HVAC - Circuit Board Fuse blows on AC Switch

1

One of the most aggravating—and rather common—issues with cooling systems involves the AC system tripping the breaker or blowing the fuse in the electrical control box when it cycles on. Repeatedly running the fuse box and changing the fuse is not only cumbersome and time-consuming, but likely also a sign of a greater problem with your cooling system or your electrical circuits. This type of problem is not something you want to fool around with yourself! Anything relating to electricity requires a skilled HVAC technician.

Common Reasons Your AC Fuses Keep Blowing

Problems with your fuse box, your circuit, and/or your central power supply.The most logical cause of your air conditioner tripping a breaker or blowing a fuse when it comes on stems from a problem with the electrical connection, the power supply, or the circuit that powers the system. Breakers and fuses are designed to trip or blow when too much voltage is sent through the line. Simply inserting a larger fuse...
0 0
2
1 Answer

How do I fix my air conditioner/furnace

If the furnace wont work, neither will the ac. There should be a box by the outside unit. Open and pull the disconect out. Thats the switch. If ac is blowing fuses, its just to hard to say, but id look at the electrical part. Mice love it their andwill chew wires. Its sounds like a short, but worse case the ac compressor is locking up. This can be solved with a hardstart kit. The condenser fan may be shot as well, or by itself. Its possible you have a bad duel capacitor, but that usally wont let it start at all. If its a freon issue, this will kick the unit out, but not trip breakers. Be sure the coil drain on top of furnace is clear, or whater could back up and get in the electronics of the furnace, blowing the furnace fuse, not the ac. Id get a bettter tech out there and just take it off the rent. Your landlords guy should have this figured on the first try. But if you have no electrical experience, leave it be. The...

0 0
3

A simple trick to finding a short is to replace the blown fuse with a pair of spade terminals, then use small jumper wires to connect them to a twelve volt light bulb. A brake light bulb works well. When the circuit is live and the short is present, the bulb will be full brightness and hot so be sure it is not laying on the carpet or against a plastic door panel. Now you can unplug electrical connectors and move things around to see what makes the short go away. When it does, the bulb will get dim or go out.

For intermittent problems like yours the bulb may be dim already. Watch what takes place when it gets bright. That is when the short is occurring. It could be due to the rocking of the engine when you shift between reverse and drive. It could be due to the body flexing when you drive over bumps in the road. The bulb limits current to a safe value when the short occurs, in this case about one amp. If the circuit will not work with a brake light in the circuit, try a...

0 0
4

by Dadan

Central Ac breaker

Fuse Metal Box

Time Delay Cartridge Fuses

Fuses Holder

What is central air conditioner fuse?

An air conditioner fuse prevents any parts of HVAC to overload or overheat.

Is a safety (device) that tells the HVAC unit, ok - you supposed to draw 30 Amp. If any part of you draw more than 30 Amp, I’m gonna turn you off.

The fuse box should be in the line of vision; it should be within REACH from the condenser unit location. The fuse for HVAC unit is Heavy duty time delay cartridge fuses. The fuse is within the fuses holder.

The within REACH disconnect is in metal box. It is either a handle that you pull out, within this handler, there is two fuse in the fuse holder. Or there is breaker.

If there isn’t disconnect box within REACH, there should be breaker box within 5 feet from the condenser unit. The condenser switches are...

0 0
5

This worked for me today!

I just had the same problem after I disconnected and reconnected the battery. The drivers side blew hot all the time no matter what the settings were and the passenger side worked OK. This happened to me about a year ago, but started working OK after I turned off the engine are restarted it. I have not had the problem until a couple of days ago. This time, turning off the engine or ignition would not reset it.

I noticed that the drivers side would blow cold air when the ignition is first turned on, then after about 10 seconds would go to hot. This means the controller and motor actuator are working.

This is what I did to fix it.

Adjusted the passenger side to full hot and the drivers side to full cold and put the system in auto mode.

Then, turned off the ignition and turned it back on. In auto mode you will see the fan speed auto adjusting up and down.

Then, I reversed the settings, drivers full hot (90) and the...

0 0
6

When you wake up on a cold winter’s morning to find your vents blowing nothing but cold air, everything else on the day’s “to-do list” takes second place to fixing your heater! This recently happened to us, and instead of working (I work from home), I decided to fix it myself. So in this article, you’ll learn how to troubleshoot a gas furnace.

Now before I get into the basics of troubleshooting a gas heater, I’d like to address the warning mechanism Trane has in place to notify the homeowner of an error. Instead of a nice little beep or an orange or yellow light coming on, Trane has decided to blow cold air to let you know that something’s not right. Here’s my thought process on that…..as if it’s not bad enough that the heater went out, now they have to blow cold air to cool your house down even more. Let’s freeze them out of house and home…that will get their attention!

Just dumb.

Anyway, one with my “how to.”

My particular furnace model is a Trane...

0 0